Safety Precautions
mrcool.com
Note about Flourinated Gases:
1.
2.
3.
4.
5.
6.
8.
9.
10.
11.
12.
13.
14.
15.
7.
6.
Install the unit in a firm location that can support the unit’s weight. If the installation location
cannot support the weight, or the installation is performed improperly, the unit may fall and
cause serious injury and/or damage.
For all electrical work, follow all appropriate wiring standards, regulations, and the Installation
Manual.
You must use an independent circuit to supply power. Do not connect other appliances to the
same circuit. Insufficient electrical capacity or defects in electrical work can cause electrical
shock or fire.
Connect electrical cables tightly and clamp them securely to prevent external forces from
damaging the terminal. Improper electrical connections may overheat, causing fire and/or
electrical shock.
All wiring must be properly arranged to ensure that the control board cover can close properly.
If the control board cover is not closed properly, it can lead to corrosion and cause the
connection points on the terminal to overheat , causing fire and/or electrical shock.
In certain functional environments, such as kitchens, server rooms, etc., the use of specially
designed air-conditioning units is highly recommended. If the power or thermostat wires are
damaged, they must be replaced by an authorized technician in order to avoid hazard.
This appliance can be used by children aged 8 years and older and persons with reduced
physical, sensory, or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children should not play with the appliance. Cleaning and user
maintenance should not be made by children without supervision.
The air conditioner unit can only be cleaned after it has been turned off and disconnected from
power, otherwise electric shock may occur.
If installed in a compact space, ensure that there is adequate ventilation in case of leakage.
Concentration of refrigerant gas can lead to explosion and other hazards.
The fixed wires connecting to this appliance must be configured with an all-pole disconnect
under voltage class III.
Wear safety glasses, protective clothing, work gloves, and have a fire extinguisher available
during installation.
Use a quenching cloth for brazing operations.
This air-conditioning unit contains R410A flourinated gases.
The refigerant gas may not have an odor, thus this should not be considered a means of leak
detection.
Installation, service, maintenance, and repair of this unit must be performed by a certified techni-
cian.
Product uninstallation and recycling must be performed by a certified technician.
If the system has a leak-detection system installed, it should be checked for leaks at least every 12
months.
Keep a record of all leak checks for the lifetime of the unit.