Electrical Power Requirements
MTS Exceed™ Series 40 Site Preparation Guide System Specifications
21
Electrical Power Requirements
The following table provides the electrical power requirements of various load
frame types.
Note Electrical connections must be made by qualified personnel and conform to local codes and regulations.
Local electrical codes supersede any information found here.
Electrical Power Requirements
M
ODEL
V
OLTAGE
F
REQUENCY
C
URRENT
M
AXIMUM
P
OWER
R
EQUIREMENT
E42 Single phase
200 - 230 V AC
50/60 Hz
3 Amps 600 W
E43 (10 kN)
E44 (10 kN)
Single phase
200 - 230 V AC
50/60 Hz
3 Amps 600 W
E44 (30 kN) Single phase
200 - 230 V AC
50/60 Hz
6 Amps 1200 W
E45 ( 100 kN) Single phase
200 - 230 V AC
50/60 Hz
10 Amps 2000 W
E45 (300 kN) Three phases
380-415 V AC or
440-480 V AC
optional
50/60 Hz 6.8 Amps 5000 W
E45 (600 kN) Three phases
380-415 V AC or
440-480 V AC
optional
50/60 Hz 7.2 Amps 5000 W
Facility Power
Requirements:
Provide a dedicated circuit for the machine, computer, and monitor.
OverVoltage Category: II
Pollution Degree: 2

Other manuals for MTS Systems Exceed 40 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems Exceed 40 Series and is the answer not in the manual?

MTS Systems Exceed 40 Series Specifications

General IconGeneral
BrandMTS Systems
ModelExceed 40 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals