Section 3
Fault Screens
Low CO2 Warning – Change Bottle to Re-Set
Note: Co2 switch is an option, not standard tment“
TYPE A – Carbonator Pump Timed-Out (Running for too long) - Turn OFF for 10 seconds
to Re-Set
TYPE B – Fridge Timed-Out (Running for too long) - Turn OFF for 10 seconds to Re-Set
LOW GAS – CHANGE
BOTTLE! 1=CANCEL
FAULT TYPE: -A
CONSULT MANUAL
DISPENSE MODE
Once the unit has been set up, the unit can be switched on and it will automatically
go into dispense mode if no keys are pressed. The dispense is push to pour and it will
dispenseamaximumofa10secondpourwhilethechosenavourbuttonispressed.
If a top up is required, re-press the key to instigate a second 10 second pour time
window.
CARBONATOR FILL TIME OUT
Intheeventofthewatersupplybeingturnedo,ablockageintheinternalwater
circuit, carbonator pump failure or a freeze up, the system has an in built time out
whichwillturnothecarbonatorpumpafteraperiodof45secondsifthecarbonator
bowlfailstoll.Ifthishappens,thedisplaywillreadFAULTTYPEB-CONSULTMANUAL
(SEEABOVE).Beforeresettingthesystem,thefaultmustberectied.Turnounitfor
10 seconds to reset.
RE- PRIMING THE SYSTEM IF THE BAG IN BOX SYRUP RUNS OUT
If the bag in box of syrup runs out, then the system needs to be re-primed following
connection of a new one. Follow the syrup priming procedure to re-prime the syrup
lines. There should be no need to re-brix the system.