Page #23 background image
22
N E T A F I M T E C H L I N E
®
C V D E S I G N G U I D E
N E T A F I M T E C H L I N E
®
C V D E S I G N G U I D E
TECHNICAL
DATA
APPLICATIONS:
Subsurface or on-surface installations
Slopes
Curved, angular or narrow areas
High traffic/high liability areas
Areas subject to vandalism
High wind areas
Turf, shrubs, trees, flowers
At-grade windows
Sports turf
Tennis courts
SPECIFICATIONS:
Dripper Flow Rates
(GPH): 0.26, 0.4, 0.6, 0.9
Dripper Spacings:, 12", 18", 24" (24" is available in 0.6
& 0.9 GPH flow rates)
Pressure Compensation Range: 14.7 to 70 psi
Maximum System Pressure: 50 psi
Tubing Diameter: 0.66” O.D., 0.56" I.D.
Coil Lengths: 100', 250', 1,000'
FEATURES/BENEFITS:
Each Dripper has a built-in, 2 psi Check Valve:
- All drippers turn on and off at the same time
- Minimizes water loss
- Holds back up to
4
1
/2
feet of water
- No low drainage; great on slopes
- More precise watering - Entire lateral begins operating at the same time
Built-in Physical Root Barrier: Drippers are protected from root intrusion without chemical reliance
Dark Brown Color: Visually identifies Techline CV, better blending into surrounding colors of the
landscape
Pressure Compensation: All drippers deliver equal flow across the length of the lateral
Unique Flow Path: Turbonet technology allows for better control of water flow and less chance of
clogging
Single hole dripper outlet from tubing:
- Better protection against intrusion
- Allows the dripperline to be used in subsurface applications without chemical protection
Water is captured from the center of the tubing, ensuring that only the cleanest water is used
No Air/Vacuum Relief Valve is required: Installations are faster and less expensive
No Automatic Line Flushing Valve is required: Because the dripperline is designed to hold water in
the tubing after shut-down, a manual flush may be used
(TLSOV or TLFIG8)
Techline Compatible: Same ID/OD as Techline, works with all Techline fittings and no pipe clamps
are needed under 50 psi
Installations are faster and less expensive
Techfilter Compatible: Provides a limited lifetime warranty against root intrusion
Techline CV
Dripperline

Table of Contents

Other manuals for Netafim TECHLINE CV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim TECHLINE CV and is the answer not in the manual?

Netafim TECHLINE CV Specifications

General IconGeneral
BrandNetafim
ModelTECHLINE CV
CategoryIrrigation System
LanguageEnglish

Related product manuals