6-MAINTENANCE
Hydraulichoses
WARNING
Escapinguid!
Hydraulicuidordieselfuelleakingunderpressurecanpenetratetheskinandcauseinfectionor
otherinjury.Topreventpersonalinjury:Relieveallpressurebeforedisconnectinguidlinesorper-
formingworkonthehydraulicsystem.Beforeapplyingpressure,makesureallconnectionsaretight
andallcomponentsareingoodcondition.Neveruseyourhandtocheckforsuspectedleaksunder
pressure.Useapieceofcardboardorwoodforthispurpose.Ifinjuredbyleakinguid,seeyour
doctorimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0178A
Checkfuel,coolantandhydraulichosesevery2years
orevery2000h(whichevercomesrst).
Checkingfuel,coolantandhydraulichoses
Makesuretherearenoleaksfromthehydraulicsystem
hoses(fuel,coolant,hydraulic),plugs,connectionsand
ttings.Checkthatallnutsandscrewsarecorrectly
tightened.Intheeventofproblems,repair,changeor
tightenthecomponentsconcerned.
6-59