EMERGENCY PROCEDURES
Engine failure (in height up to 200 m)
- lead the MPG into free flight
- in low height, land in the line of flight – try to avoid any barriers
- if you are high enough, land into an open area without any barriers, against the
wind if possible
Engine failure (in height over 200 m)
- lead the MPG into free flight
- check fuel condition
- in case of breaking fuel supply, try to restore it and start the engine
- if your paramotor has not got an electric starter, it do not start or your high is
under 200 m, choose suitable area for your landing and land as described
above.
Fire
- switch off the ignition
- do not try to start the engine
Vibrations
if abnormal vibrations appear it is necessary:
- to set engine revolutions to the mode, where vibrations are as small as
possible
- to do emergency landing
- if vibrations increase, land in the terrain with engine switched off.
Using the rescue system
In case of emergency or definitive loss of control of your paraglider, switch the
ignition off, right hand grasps the rescue parachute handle, pull and release it, and
throw it sideways behind yourself. The position of the handle depends on the
rescue parachute positioning – at the bottom, on the side or in the front (standard in
the front in a front container).