OPERATING INSTRUCTIONS
SINGLE PUMP SYSTEM
INITIAL START-UP
Your spa will enter Priming Mode (Pr ) when it is energized.
During Priming Mode, press “Jets” button repeatedly
and be sure the pump is free of air. Priming Mode lasts
less than 5 minutes. Press “Warm” to exit. After Priming
Mode, the spa will run in Standard Mode (see Mode
section).
Pump 1 low-speed is responsible for heating and ltration
and will be referred to simply as the pump.
In multi-button sequences, if the buttons are pressed too
quickly in sequence, they may not register.
Low speed pump will run every 30 minutes from 2 to 5
minutes to check the tubs water
TEMP CONTROL
(80°F - 104°F / 26°C - 40°C)
The last measured water temperature is constantly
displayed. The water temperature displayed is current only
when the pump has been running for at least 1 minute.
To display the set temperature, press “Warm” or “Cool”
once. To change the set temperature, press a temperature
button again before the display stops ashing. Each press of
“Warm” or “Cool” will adjust the set temperature. After three
seconds, the display will stop ashing and begin to display
the current spa temperature.
JETS
Press “Jets” to turn the pump on or off, and to shift between
low and high speeds. If left running, the pump will turn off
after a preset length of time of 2 hours for low speed and 15
minutes for high speed. Low speed may run automatically at
times, during which it cannot be deactivated from the panel,
but high speed may be operated. The ozone generator (if
installed) will activate anytime low speed is running.
LIGHT
Press “Light” to operate the spa light. Turns off after 4 hours.
MODE
Mode is changed by pressing “Warm” or “Cool” then “Light”.
Some tubs will have the modes disabled from the factory.
STANDARD MODE maintains set temperature. St will be
displayed momentarily when you switch into Standard
Mode.
ECONOMY MODE heats the spa to the set temperature
only during lter cycles. Ec will display when water temp
is not current, and will alternate with water temp when the
pump is running.
SLEEP MODE heats the spa to within 20°F/10°C of the set
temperature only during lter cycles. SL will display when
water temp is not current, and will alternate with water temp
when the pump is running.
PRESET FILTER CYCLES
The rst preset lter cycle begins 6 minutes after the spa is
energized. The second preset lter cycle begins 12 hours
later. Filter duration is programmable for 1, 2, 3, 4, 5, 6, 7, or
8 hours. The default lter time is 1 hour. To program, press
“Warm” then “Jets.” Press “Warm or Cool” to adjust. Press
“Jets” to exit programming.
AUTOMATIC POLLING (in Standard Mode)
The pump will activate for 2-5 minutes every 30 minutes to
check the temperature. This also happens whenever the
temperature is adjusted.