54
Included Accessories
Remote Controller (× 1)
Mounting Bracket (× 1)
Flat Head Tapping Screw (× 2)
Dry Wall Anchor (× 2)
Flat Head Machine Screw (× 2)
(For junction box installation)
Round Head Machine Screw (× 2)
11.3 RC-9018M
Limiting the Maximum Output Temperature
The maximum output temperature can be limited to
prevent discharging hot water at too high of a
temperature.
Default setting of maximum output temperature is
120°F (50°C).
1. Turn the Water Heater off by pressing the
button on the Remote Controller.
2. Press and hold the button until a sound is
heard (approximately 2 seconds).
[120°F/50°C] appears on the display.
3. Set the upper limit of the hot water temperature
using the / buttons.
• For Fahrenheit (°F): 125- 140°F (In 5°F
intervals)
• For Celsius (°C): 55°C, 60°C
4. Set the button to ON when continuing to
use the unit as is. Otherwise, let the unit sit for
approximately 30 seconds.
• When changing the temperature, make
sure to confirm with the customer that the
temperature of the Hot Water will be very high
and that there is a risk of scalding.
• Hot water temperatures over 125°F (52°C) can
cause severe burns instantly or death from
scalding.
DANGER
Installation of the Remote Controller