DN-5262 • 10/31/05 — Page 1 of 10
GENERAL
The AFP-300 and AFP-400 are compact, cost-effective, in-
telligent fire alarm control panels with a total capacity of
up to 563 points and an extensive list of powerful features.
The AFP-300/400 integrates conventional output circuits,
such as notification, telephone, and speakers, with the in-
telligent features of one or two signaling line circuits (SLC)
and 198 or 396 intelligent/addressable points.
FEATURES
• One loop (AFP-300) or two loops (AFP-400) Style 4, 6 or 7.
• 198 intelligent devices per loop (99 intelligent detec-
tors and 99 intelligent modules).
• 396 intelligent device capacity on the AFP-400; 198 on
the AFP-300.
• VIEW®, HARSH™, Advanced Multi-Sensor (AMS) op-
tions.
•
Up to 68 internal circuits/relays, plus 99 programmable
zone output relays for a total capacity of 563 points.
• Four integral Notification Appliance (signal) Circuits
(NACs), Style Z or Y (Class A or B).
• 6.0 A power supply, plus 6.0 A expanders.
• NACs may be programmed for Steady, March Time,
Temporal, California code, or Canadian Two-Stage.
• Modified California code, pulsed on time.
• Tornado Warning activates different Notification Appli-
ance Circuit code.
• Alarm, Trouble, Supervisory, and Security relays, stan-
dard.
• Peer-to-peer network-ready.
• Intelligent features:
Manual sensitivity adjustment — 9 levels.
Pre-alarm intelligent sensing — 9 levels.
Day/Night automatic sensitivity adjustment.
Drift compensation.
Multi-detector algorithm involves nearby detectors
in alarm decision.
Auto detector test (meets NFPA 72).
Maintenance alert (two levels).
Self-optimizing pre-alarm adjusts pre-alarm level to
environment automatically.
Activate local sounder base on pre-alarm.
LED blink control for sleeping areas.
Automatic device type check.
Trouble after 20 detector verifications.
• Releasing features:
Ten independent hazards.
Sophisticated cross-zone (three options).
Delay timer and Discharge timers (adjustable).
Abort (four options).
S635
• Sensitivity windows:
ION — 0.5 to 2.5%/foot obscuration.
PHOTO — 0.5 to 2.35%/foot obscuration.
MULTI-SENSOR — 0.71 to 4.0%/foot obscuration.
VIEW® — 0.03 to 1.0%/foot obscuration.
• Low-pressure CO
2
support:
Expanded soak timer – 0 to 9999 seconds.
Manual release delay (10 seconds) type ID.
“Second shot” monitor module type ID.
Triple-coded notification circuit type ID.
• Voice and telephone features:
Solid state message generation.
Hard-wired voice control module options (single-
address mode modules).
7170-0028:182
7165-0028:181
CS118/733
AFPAFP
AFPAFP
AFP
-300-300
-300-300
-300
and and
and and
and
AFPAFP
AFPAFP
AFP
-400-400
-400-400
-400
Analog Fire PAnalog Fire P
Analog Fire PAnalog Fire P
Analog Fire P
anelsanels
anelsanels
anels
October 31, 2005
DN-5262 • A-103
Section: Intelligent Fire Alarm Control Panels
California
State Fire
Marshal
City of
Chicago
CLASS 1: 1291E
CLASS 2: 1729E
MEA
17-96-E
(AFP-400)
17-96-E Vol. II
(AFP-300)
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice.
For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118
12 Clintonville Road, Northford, Connecticut 06472
HARSH™ and NOTI•FIRE•NET™ are trademarks;
VeriFire
®,
VIEW® and NOTIFIER® are registered trademarks of Honeywell
International Inc. Microsoft® and Windows® are registered
trademarks of the Microsoft Corporation.
City of
DENVER
(AFP-400)
5262cov.tif, NotiWH2001.wmf, notifblk.WMF