8
Rated heating input power /
current A
7030W /12.5A
8460W / 15.1A
Ratedhot water heating
capacityW
14500W
18600W
Rated floor heating input power /
current A
6500W / 11.5A
8340W / 14.9A
Maximum input power / current
A
9280W / 16.6A
12030W / 21.5A
Refrigerant / weight
R410A/4800g
R410A/5000g
Specification for control panel
fuse wire
T6.3AL/250V
T6.3AL/250V
Ring temperature working range
()
-2543
-2543
Water temperature working
range()
760
760
Water pressure working range
MPa
≤0.45
≤0.45
Rated water flow /h
3.44
4.3
outline dimension (mm
1211*568*1496
1211*568*1496
Water pipe diameter
G1-1/2"(inner)
G1-1/2"(inner)
III. Installation
1. Operating Instruction
1. Safety Warning
(Not following the operation below, it may cause user injury or damage to the unit)
The heat pump
must be installed
by a professional
Installation or
maintenance of
the unit, must
ensure that the
grounding wire is
grounded safely
and reliably, and
is strictly
prohibited.
When powered off
or cannot be used,
the water of the
heat pump unit
must be released,
otherwise the
warranty will not
be guaranteed after
the damage.
Do not use mobile
outlets, damaged
power cords and
outlets
The inner tank is
forbidden to be
energized before
filling full of water