290
Startup Settings and Maintenance Section 6-6
Note The CS-series CS1 CPU Units are shipped without the backup battery
installed, and the CPU Unit’s internal clock will be read 00/01/01 00:00:00 or
possibly another value when the battery is connected. To use the clock func-
tions, connect the battery, turn the power ON, and set the time and date with a
Programming Device (Programming Console or CX-Programmer) or the FINS
command (07 02, CLOCK WRITE). The CPU Unit’s internal clock will begin
operating once it has been set.
Auxiliary Area Flags and Words
Related Instructions
6-6-7 Program Protection
The CS/CJ-series user program can be write-protected and completely pro-
tected (read/write protection).
Write-protection Using the DIP Switch
The user program can be write-protected by turning ON pin 1 of the CPU
Unit’s DIP switch. When this pin is ON, it won’t be possible to change the user
program from a Programming Device (including Programming Consoles).
This function can prevent the program from being overwritten inadvertently at
the work site.
It is still possible to read and display the program when it is write-protected.
Name Addresses Function
Clock data A35100 to A35107 Second: 00 to 59 (BCD)
A35108 to A35115 Minute: 00 to 59 (BCD)
A35200 to A35207 Hour: 00 to 23 (BCD)
A35208 to A35215 Day of the month: 00 to 31 (BCD)
A35300 to A35307 Month: 00 to 12 (BCD)
A35308 to A35315 Year: 00 to 99 (BCD)
A35400 to A35407 Day of the week:
00: Sunday, 01: Monday,
02: Tuesday, 03: Wednesday,
04: Thursday, 05: Friday, 06: Saturday
Start-up Time A510 and A511 Contain the time at which the power
was turned on.
Power Interruption
Time
A512 and A513 Contain the time at which the power
was last interrupted.
Total Power ON Time A523 Contains the total time (in binary) that
the PLC has been on in 10-hour units.
Instruction Name Function
SEC(065) HOURS TO SEC-
ONDS
Converts time data in hours/minutes/seconds
format to an equivalent time in seconds only.
HMS(066) SECONDS TO
HOURS
Converts seconds data to an equivalent time in
hours/minutes/seconds format.
CADD(730) CALENDAR ADD Adds time to the calendar data in the specified
words.
CSUB(731) CALENDAR SUB-
TRACT
Subtracts time from the calendar data in the
specified words.
DATE(735) CLOCK ADJUST-
MENT
Changes the internal clock setting to the setting
in the specified source words.

Table of Contents

Other manuals for Omron CJ1M-CPU series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ1M-CPU series and is the answer not in the manual?

Omron CJ1M-CPU series Specifications

General IconGeneral
BrandOmron
ModelCJ1M-CPU series
CategoryController
LanguageEnglish

Related product manuals