E5CSL/E5CWL/E5EWL
3
Input Ranges
Models with Thermocouple Inputs
Default setting: 0
Applicable standards (K, J, T, R, S): JIS C1602-1995 and IEC 60584-1
Models with Resistance Thermometer Inputs
Default setting: 8
Applicable standards (Pt100): JIS C1604-1997 and IEC 60751
Alarm Types
Select alarm types out of the 11 alarm types listed in the following
table.
Note: Alarms with a Standby Sequence
The alarm is blocked until the first safe-state is reached.
Unwanted alarm during start-up are prevented.
Example: Deviation Lower Limit Standby Sequence ON
The standby sequence is cleared when the alarm OFF condition has
been met.
The standby sequence is started again when any of the following
conditions is met.
Operation is started (power is turned ON or operation is switched
from stop to run).
The alarm value is changed.
The temperature input offset is changed.
The set point is changed.
Model
(temperature input)
Set value Input type
Range
C F
TC input
0
K
200 to 1,300 300 to 2,300
1 20.0 to 500.0 0.0 to 900.0
2
J
100 to 850 100 to 1500
3 20.0 to 400.0 0.0 to 750.0
4
T
200 to 400 300 to 700
5 199.9 to 400.0 199.9 to 700.0
6 R 0 to 1,700 0 to 3,000
7 S 0 to 1,700 0 to 3,000
Model
(temperature input)
Set value Input type
Range
C F
Pt input
8
Pt100
-200 to 850 -300 to 1500
9 -199.9 to 500.0 -199.9 to 900.0
Setting Alarm type Positive alarm
value (X)
Negative alarm
value (X)
0 No alarm Output OFF
1
Deviation upper/
lower limit
Always ON
2
Deviation upper
limit
3
Deviation lower
limit
4
Deviation upper/
lower range
Always OFF
5
(See
note.)
Deviation upper/
lower limit standby
sequence ON
Always OFF
6
(See
note.)
Deviation upper
limit standby
sequence ON
7
(See
note.)
Deviation lower
limit standby
sequence ON
8
Absolute value
upper limit
9
Absolute value
lower limit
10
(See
note.)
Absolute value
upper limit standby
sequence ON
11
(See
note.)
Absolute value
lower limit standby
sequence ON
12 Do not set.
ON
OFF
SP
XX
SP
X
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
SP
XX
ON
OFF
SP
XX
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
Standby sequence cleared
Alarm value
Alarm with standby sequence
Process value
Time
Alarm without standby sequence
Alarm hysteresis
(always 0.2 °C/°F)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

Other manuals for Omron E5CWL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5CWL and is the answer not in the manual?

Omron E5CWL Specifications

General IconGeneral
BrandOmron
ModelE5CWL
CategoryTemperature Controller
LanguageEnglish

Related product manuals