110
Ratings
Item H3CA-A/H3CA-FA H3CA-8 H3CA-8H
Rated supply voltage 24 to 240 VAC (50/60 Hz),
12 to 240 VDC (permissible
ripple: 20% max.)
100/110/120, 200/220/240 VAC, (50/60 Hz),
24 VDC (permissible ripple: 20% max.) (see note)
Operating voltage range 90% to 110% of rated supply
voltage
85% to 110% of rated supply voltage
Power consumption AC: approx. 2 VA
DC: approx. 2 W
AC: approx. 10 VA/1 W
DC: approx. 1 W
AC: approx. 10 VA/1.5 W
DC: approx. 2 W
Control outputs 3 A at 250 VAC, resistive load (cos
%
=1)
Note: Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC.
Characteristics
Accuracy of operating time
!
0.3%
!
0.05 s
Influence of voltage
Influence of temperature
Setting error
!
0.5%
!
0.05 s
Reset time H3CA-A/-FA: 0.5 s max.
H3CA-8H/-8: 0.1 s max.
Insulation resistance 100 M
$
min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and
between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 100 m/s
2
(approx. 10G)
Ambient temperature Operating: --10
"
Cto55
"
C
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (3 A at 250 VAC, cos
%
= 1 at 1,800 operations/h)
Approved standards UL (File No. E41515), CSA (File No. LR22310), SEV
Weight H3CA-A: approx. 110 g
H3CA-FA: approx. 190 g
Engineering Data
Switching operations (x 10 )
3
Load current (A)
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos
%
=1).
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
Note: 1. The H3CA Series has been tested forthefollowing:impulsevoltages,nois
e
(via noise simulator, for L loads, and for relay oscillation), and resistance t
o
static electricity.
2. Minimum applicable load (P reference values):
H3CA-A(FA), H3CA-8H: 100 mA at 5 VDC
H3CA-8: 10 mA at 5 VDC