Selection Guide
4
Classification Solid-state Timer Digital Timer
Model H3FA H3T H5CL
Features DIP type Timer for PC
board-use provides contact
and solid-state output
PCB-mounting time unit for
high-frequency applications
Easy-to-see and
easy-to-operate DIN 48 x
48-mm Digital Timer with
IP66/NEMA 4 protection
Appearance and dimensions
20
33
6.5
14.3
48
48
78.5
Time range (60 Hz) 0.1 s to 60 min 0.1to60min 0.001 s to 999.9 h
Supply voltage 5, 6, 12, or 24 VDC;
5/6, 12/24 VDC
12 to 24 VDC 100 to 240 VAC (50/60 Hz),
12 to 24 VDC
Power consumption 80 to 330 mW 60 mW, 120 mW Approx. 10 VA, 3 W
Accuracy of operating time
!
0.5%
!
2%
!
0.01%
!
0.07 s (power start)
!
0.005%
!
0.03 s (control signal start)
Control output Contact output: 3 A at 250 VAC
Solid-state output: 150 mA at
30 VDC
Solid-state: 100 mA 3 A at 250 VAC
Contact
configuration
Time-limit SPST-NO + SPST-NC,
solid-state
SPST-NO SPDT Solid-state
Instantaneous --- --- --- ---
Life expectancy 10 x 10
6
operations --- 10 x 10
6
operations
EMC --- --- Conforms to EN50081-2,
prEN50082-2
Approved standards UL, CSA --- UL, CSA
Page 137 145 151
Classification Digital Timer
Model H5BR H5CR H5AN
Features 72 x 72-mm Timer with
easy-to-use functions
1/16 DIN Timer with
easy-to-use function
DIN-sized (72 x 72 mm) Quartz
Timer with multiple functions
Appearance and dimensions
72
72
106
48
48
69.7
Time range (60 Hz) 0.01 s to 9999 h 0.001 s to 9999 h 0.01 s to 9999 h
Supply voltage 100 to 240 VAC (50/60 Hz),
24 VAC/12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz), 12 to
24 VDC
100 to 240 VAC (50/60 Hz),
12 to 24, 48, or 100 VDC
Power consumption 8VA,5W 3VA/1W,5VA,2W 10 VA, 5 W
Accuracy of operating time
!
0.01%
!
0.05 s (power start)
!
0.005%
!
0.03 s (control signal
start)
!
0.01%
!
0.05 s (power start)
!
0.005%
!
0.03 s (control signal
start)
!
0.01%
!
0.05 s (power start)
!
0.005%
!
0.03 s (control signal
start)
Control output Contact output: 5 A at 250 VAC Contact output: 5 A at 250 VAC Contact output: 3 A at 250 VAC
Solid-state output: 100 mA at
30 VDC
Contact
Time-limit SPDT, solid-state SPDT Solid-state SPDT, solid-state
configuration
Instantaneous --- --- --- ---
Life expectancy 10 x 10
6
operations 10 x 10
6
operations 10 x 10
6
operations
EMC Conforms to EN50081-2,
prEN50082-2
Conforms to EN50081-2,
prEN50082-2
---
Approved standards UL, CSA UL, CSA UL, CSA
Page NO TAG 174 189