H7CL
H7CL
4
Operation
DIP Switch Setting
Pin
no.
Item OFF ON
1
Counting speed
30 cps 5 kcps
2
Input modes
Up (Increment)
Down (Decrement)
3, 4
Operating modes
See table below
.
5
One-shot time
(see note 1)
500 ms
50 ms
6
Reset min. pulse width 20 ms
1 ms
Note: 1. DIP
switch settings change when the power is turned on. Its setting changes
become
disabled while the power is on.
2.
The one-shot time is valid only when the C mode or K mode is selected.
Operating Modes
3 4 Operating
modes
OFF OFF N Count Stop, Output Hold Mode
The output and present value are on hold until reset input is ON.
ON OFF F Over-count, Output Hold Mode
The Counter continues incrementing/decrementing the present value but the output is on hold until reset.
OFF ON C Auto-reset, One-shot Output Mode
The Counter is automatically reset when counted up. The control output is a one-shot output type.
ON ON K Over-count, One-shot Output Mode
The Counter continues incrementing/decrementing the present value but the output is a one-shot output
type.
Note:
Switches 1 to 6 are all set to OFF before shipping.
Operating Modes
N
Mode
Counting stop, output is on hold.
Up (Increment) Mode
Down (Decrement) Mode
Count input
Gate
input
Output
0
Reset input
Set
value
Count input
Gate
input
Output
0
Reset input
Set value
F
Mode
Over-count, output is on hold.
Up (Increment) Mode
Down (Decrement) Mode
Set value
Count input
Gate
input
Output
0
Reset input
Set value
Count input
Gate
input
Output
0
Reset input
(The
same DIP
switch settings
apply to AC and
DC models)