157
Key Sequence
The following example shows inputting a new constant and changing from a
constant to a word designation.
Inputting New SV
0000
0000
TIM
00
0201SRCH
TIM 00
0201 TIM DATA
#0123
0201 TIM DATA
T00 #0123 #????
0201 TIM DATA
T00 #0123 #0124
0201 TIM DATA
#0124
0201 DATA?
T00 #0123 c???
0201 DATA?
T00 #0123 c 10
0201 TIM DATA
10
7-4 Program Backup and Restore Operations
Program Memory (UM) can be backed-up on a standard commercially avail-
able cassette tape recorder. Any kind of dependable magnetic tape of ade-
quate length will suffice. To save a 16K-word program, the tape must be 30
minutes long. Always allow about 5 seconds of blank tape leader before the
taped data begins. Store only one program on a single side of a tape; there is
no way to identify separate programs stored on the same side of the tape. If
a program is longer than will fit on one side, it can be split onto two sides.
Be sure to label the contents of all cassette tapes clearly.
Use patch cords to connect the cassette recorder earphone (or LINE-OUT)
jack to the Programming Console EAR jack and the cassette recorder micro-
phone (or LINE-IN) jack to the Programming Console MIC jack. Set the cas-
sette recorder volume and tone controls to maximum levels.
Example
Program Backup and Restore Operations Section 7-4

Table of Contents

Other manuals for Omron SYSMAC C28K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C28K and is the answer not in the manual?

Omron SYSMAC C28K Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C28K
CategoryController
LanguageEnglish

Related product manuals