SERVICE
AND
MAINTENANCE
CRANKCASE
OIL
Fill
to
the
“F”
mark
on
the
oil
level
dipstick.
Use
a
good
quality
detergent
oil
that
meets
the
API
(American
Petroleum
Institute)
service
designations
SD
or
SD/CC.
Oil
should
be
labeled
as
having
passed
the
MS
sequence
tests
(also
known
as
the
ASTM
G-IV
sequence
tests)
and
the
MIL*L*2104B
tests.
Use
the
proper
SAE
number
of
oil
for
the
expected
temperature
conditions.
Do
not
mix
brands
or
grades.
Extremely
dusty
or
low
tempera*
tore
conditions
require
oil
change
at
50
hours.
Oil
capacity
is
4
U.S.
quarts.
FIG.
13.
OIL
LEVEL
INDICATOft
CRANKCASE
BREATHER
Lift
off
rubber
breather
cap.
Carefully
pry
valve
from
cap.
Otherwise
press
hard
with
both
thumbs
on
top
of
the
cap
and
fingers
below
to
release
valve
from
rubber
cap.
Wash
this
fabric
flapper
type
check
valve
in
a
suitable
solvent.
Dry
and
install.
Position
perforated
disc
toward
engine.
AIR
CLEANER
Clean
screen
and
cup
in
a
suitable
solvent.
Refill
to
level
indicated
on
cup.
Use
the
same
type
of
oil
as
used
in
crankcase.
Refer
to
Operator
Maintenance
Schedule
for
further
recommendatioi6.
FIG.
IS.
AIR
CLEANER
FIG.
14.
CRANKCASE
BREATHER
FIG.
I.
SPARK
PLUG
GAP

Other manuals for Onan CCK Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onan CCK Series and is the answer not in the manual?

Onan CCK Series Specifications

General IconGeneral
BrandOnan
ModelCCK Series
CategoryPortable Generator
LanguageEnglish

Related product manuals