3. Safety Information
DANGER: If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
CAUTION: This equipment does not have any user-serviceable parts. If the equipment needs to be opened,
you should contact technical service.
CAUTION: This symbol indicates the risk of damages to persons or material. If material damages occur,
there can be further damages which can cause death or injury to body or health. This symbol on
the equipment indicates that this user manual is to be consulted for instruction or further
information provided for safe operation.
CAUTION: This product is provided with a protective earth ground incorporated into the power cord. The
front panel switch is not a line switch. The AC power cord is the disconnecting device that
disconnects the signal generator mains circuits from the mains supply. Alternatively, an external
switch or circuit breaker, readily identifiable and easily reached by the operator, may be used as a
disconnecting device.
Installation Safety Considerations
Lifting and Carrying:
The GSG-8 is delivered with handles installed on the front panel for use while lifting and carrying. If
the weight of the equipment is too heavy to be carried by one person, use two persons and/or use
an appropriate tool. In all cases, use the handles and grips of the product to lift and carry it safely.
Never rest the GSG-8 on its rear side. This position can cause severe damage to the unit by pushing
on the rear connectors and wires.
Orientation:
The GSG-8 must be installed horizontally with the two front panel screws on top. The product logo
should be face-up.
Location:
Install your GSG-8 in an indoor, dry environment with temperatures between +0° C and +30° C.
Mounting:
The GSG-8 is supplied with rack mount ears attached to the chassis. To mount the unit in a 19” rack,
use 4 rack screws (not provided) to secure the unit, using 2 screws per side.
Ventilation Requirements:
Ensure that the equipment has a minimum of 4 in or 100 mm clearance at the front and the rear to
allow proper air ventilation.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia GSG-8 Series and is the answer not in the manual?

Orolia GSG-8 Series Specifications

General IconGeneral
BrandOrolia
ModelGSG-8 Series
CategoryReceiver
LanguageEnglish

Related product manuals