Compressor Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and restart
automatically. (Time Delay Safety Control is valid).
If the above phenomenon is repeated for 3 times, the compressor will stop totally.
The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
Purpose is to prevent dew formation on indoor unit air discharge area.
When the following conditions occur for 30 minutes continuously, anti-dew formation is controlled by indoor fan speed shift to
low (CLo to HLo):
Indoor intake air temperature is more than 24°C and less than 30°C.
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed.
This control is cancelled immediately when above condition is changed.
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
18
CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6

Other manuals for Panasonic CS-A9BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A9BKP and is the answer not in the manual?

Panasonic CS-A9BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A9BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals