Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overcooling.
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later .
The airflow volume will automatically change to Lo fan
speed.
Sleep Mode operation time is 8 hours, the operation will be
stop after 8 hour.
When used together with the Timer, the Timer has priority.
Heating Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overheating.
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
The setting temperature will be decrease by 2°C at the start
of operation and by 3°C one hour later.
The airflow volume will automatically change to Lo fan
speed. The fan speed refer to Indoor Fan Motor Control.
Sleep Mode operation time is 8 hours, the operation will be
stop after 8 hour.
When used together with the Timer, the Timer has priority.
8.5. Sleep Mode Auto Operation
8.6. Random Auto Restart Control
If there is a power failure, operation will be automatically restarted after 3 to 5 1/2 minutes when the power is resumed. It will
start with previous operation mode and airflow direction.
Restart time is decided randomly using 4 parameter:
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
Random Auto Restart Control is not available when Timer or Sleep Mode is set.
This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.7. Delay ON Timer Control
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
For Heating mode, the operation will start 30 minutes before the set time.
For Automatic mode, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
28
CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6

Other manuals for Panasonic CS-A9BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A9BKP and is the answer not in the manual?

Panasonic CS-A9BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A9BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals