Indoor Unit
Random Auto Restart Control
Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
Indoor Fan operates at Low speed.
Operation stops after 8 hours.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
Heating : Fan speed varies from Me
SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and SLo
speed. Deodorizing control is
available.
Soft Dry : Fan rotates at SLo speed.
Deodorizing control is
available.
Automatic air swing and manual adjusted
by remote control for vertical airflow.
Manually adjusted by hand for horizontal airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green) ......... Lights up in operation,
blinks in Automatic
Operation Mode judging.
SLEEP
(Orange) ......... Lights up in Sleep Mode
Operation.
TIMER
(Orange) ......... Lights up in Timer
Setting.
POWERFUL
(Orange) ... Lights up in Powerful
Mode Operation.
ECONOMY
(Green) ...... Lights up in Economy
Mode Operation.
Operation Mode
Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
Reaches the desired room temperature
quickly.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Starting Current Control
Economy Operation
To reduce electrical power consumption.
7 Minutes Time Save Control
Cooling Operation only.
Anti-Dew Formation Control
Anti-Dew Formation Control for indoor unit
discharge area.
Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
30 Minutes Time Save Control
Heating Operation only.
Hot-Start Control
At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)
4
CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6

Other manuals for Panasonic CS-A9BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A9BKP and is the answer not in the manual?

Panasonic CS-A9BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A9BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals