EasyManuals Logo
Home>Panasonic>Air Conditioner>CS-C7MKP-7

Panasonic CS-C7MKP-7 User Manual

Panasonic CS-C7MKP-7
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
Control Device Capillary Tube Capillary Tube
Refrigerant Oil cm
3
ATMOS M60 or Suniso 4GDID (450) ATMOS M60 or Suniso 4GDID (700)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 950 (33.5) R22, 1.20k (42.4)
Height(I/D / O/D) mm (inch) 290 (11-7/16) 540 (21-9/32) 290 (11-7/16) 750 (29-17/32)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) 780 (30-23/32) 1070 (42-5/32) 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 235 (9-9/32) 289 (11-13/32) 235 (9-9/32) 345 (13-19/32)
Weight Net (I/D / O/D) kg (lb) 12 (26) 37 (82) 12 (26) 53 (117)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 16 16
Drain Hose
Length mm 550 550
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 15 x 21 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 24 x 17 2 x 34 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 25.4 x 504 x 693.4:713.4 25.4 x 714 x 831.2:811.2
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 16 20
Thermostat - Mechanical
Protection Device Overload Protector -
DRY BULB WET BULB DRY BULB WET BULB
Maximum 32 23 32 23
Indoor Operation Range
Minimum 16 11 16 11
Maximum 43 26 43 26
Outdoor Operation Range
Minimum 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Specifications are subjected to change without prior notice for further improvement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-C7MKP-7 and is the answer not in the manual?

Panasonic CS-C7MKP-7 Specifications

General IconGeneral
BrandPanasonic
ModelCS-C7MKP-7
CategoryAir Conditioner
LanguageEnglish

Related product manuals