17.2 Operation Characteristics
17.2.1 CS-C7MKP-7 CU-C7MKP-7
Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 7.5m
15.000
15.200
15.400
15.600
15.800
16.000
30 31 32 33 34 35 36 37 38 39 40
Outdoor Air Temperature (°C)
Outlet Air
Temperature (°C
)
220 240
1.800
1.900
2.000
2.100
2.200
30 31 32 33 34 35 36 37 38 39 40
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
2.700
2.800
2.900
3.000
3.100
3.200
3.300
30 31 32 33 34 35 36 37 38 39 40
Outdoor Air Temperature (°C)
Current
(A)
0.550
0.560
0.570
0.580
0.590
30 31 32 33 34 35 36 37 38 39 40
Outdoor Air Temperature (°C)
Gas Side
Piping Pressure (MPa
)