TWP/TWB200 – TWP/TWB9000
25
Main Screen User Controls
1. Menu Icon – Press to display the menu icons on the sides of the display.
2. Snapshot Icon – Press to save a snapshot of any screen to a ash drive.
3. Help Icon – Press to display online help screens where available.
4. Silence Button – Press to silence the alarm screen and turn off the alarm relay.
5. Alarm Reset Button – Press to reset all alarms and restart regeneration.
6. Enable Step Button – Press to enable the manual step function.
7. Step Button – Press to step to the next regeneration state – Use with caution.
8. Standby Button – Press to place the dryer in standby and to restart the dryer.
9. Log In / Log Out Buttons – Press to log in and log out as required
Supervisor default password is SUP (all caps).
These passwords may be changed, however, if the password is lost, the display must be completely reprogrammed
in order to reset, resulting in a potential service call!
Main Screen Information Display
a. Status Message Line –
Cycles thru one or more of the following, as well as, any active alarms.
PRESS START KEY WHEN READY
Displayed only before the dryer is started for the rst time.
DRYER NOT CONFIGURED!
Displayed only before the dryer is congured for the rst time.
ALL SYSTEMS OK
Default message – No alarms. Dryer is running in normal operation.
ALARM SHUTDOWN
Regeneration has shut down.
To restart, Press the Alarm Reset button.
LOW CONTROL AIR - REGENERATION SUSPENDED
Inlet air pressure is too low to provide sufcient control air for the dryer.
Regeneration is paused until air pressure returns.
MANUAL STEPPING ACTIVE
The Step button is active – Use with Care!
GOING TO STANDBY
Standby button has been touched and the dryer is waiting to go to standby
If heating, the dryer will cool for 2 minutes before going to Standby.
DRYER IN STANDBY - REGENERATION SUSPENDED
Dryer is in standby and will wait indenitely until the Standby button has been
touched again.