13. Troubleshooting
Fault Possible cause Remedy
The compressor
does not start.
No supply voltage.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
Check the supply voltage, the power plug and the
socket-outlet.
Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
Never operate with an outside temperature of below +5° C.
Allow the motor to cool down. If necessary, remedy
the cause of the overheating.
The compressor
starts but there is no
pressure.
The non-return valve (19) leaks.
The seals are damaged.
The drain plug for condensation water (10) leaks.
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
Check the seals and have any damaged seals re-
placed by a service center.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
The hose connections have a leak.
A quick-lock coupling has a leak.
Insufficient pressure set on the pressure regulator (5).
Check the compressed air hose and tools and replace
if necessary.
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
Increase the set pressure with the pressure regulator.

Table of Contents

Other manuals for Parkside PKO 500 A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parkside PKO 500 A2 and is the answer not in the manual?

Parkside PKO 500 A2 Specifications

General IconGeneral
BrandParkside
ModelPKO 500 A2
CategoryAir Compressor
LanguageEnglish

Related product manuals