24 GB/IE
3
M / °C / °F button (Material selection,
°C or °F selection)
4
button (ON / OFF, Freeze the meas-
ured value on the display)
5
RESET button
6
Battery compartment cover
7
Battery compartment
8
Display
Moisture indicator in %
10
Material number
11
Low battery indicator
12
Lock symbol (Measured value frozen)
13
Temperature display (°C or °F)
Technical data
Operating voltage: 3 V
Battery type: 2 x LR03 / AAA
Temperature accuracy: + / - 1°C
Humidity accuracy: A: building material
below 1.4 %: +/- 0.3 %
over 1.4 %: +/- 0.5 %
B: wood material
below 30 %: +/-2 %
over 30 %: +/-4 %
Precision: see chapter “Making
measurements”
Operating temperature: 0 °C to 40 °C
Protection class: IP 20
Resolution: 0.1 %
Air humidity: up to a maximum of
80 % (relative)