Saddle
Valve
Shelf
Lock
Figure 7-6. Remove Shelf Slide
Figure 7-7. Remove Pilaster
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
7.2.1 Process Tubes and Access Valve
Refrigerant system is hermetically sealed. Use
access tubes to charge unit and check pressure.
Note: Access valves (saddle valves) are not
provided and may vary.
Access valves should never be left on the
equipment permanently as they tend to
leak over time. Install Schrader valves any
time the system has been accessed.
Figure 7-4. Process Tubes
Remove Evaporator Fan Panel STEP
STEP 1.
Remove shelves, shelf slides and pilasters from
refrigerator section nearest the evaporator coil.
To remove a full extension shelf, pull shelf out so it
is fully extended, release lock mechanism on each
slide and pull out shelf. See Figure 7-5.
To remove the slides, lift up on front of slide and
pivot slightly inward to remove from the front
pilaster key slot. Pull slide forward to remove slide
from rear pilaster key slot. See Figure 7-6.
Remove screws from pilasters and remove. See
Figure 7-7.
Figure 7-5. Remove Shelves
Refrigeration System Repair Instructions Page 7-4

Table of Contents

Other manuals for Perlick HC24WB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perlick HC24WB and is the answer not in the manual?

Perlick HC24WB Specifications

General IconGeneral
BrandPerlick
ModelHC24WB
CategoryRefrigerator
LanguageEnglish

Related product manuals