Models
Temp
Control
Type
Set Point
(F)
Set Point
Range (F)
Hysteresis
(Air Temp)
Oset Delay Display Defrost Type Timing
Fan Delay
Post Defrost
HA24RB,
HB24RS,
HC24RS,
HD24RS
Electro- Mechanical
36 33-42 17 N/A N/A N/A Off Cycle N/A N/A
HA24BB,
HB24BS
Electro-Mechanical
42 33-46 17 N/A N/A N/A Off Cycle N/A N/A
HA24WB,
HB24WS,
HC24WS,
HD24WS
Electro-Mechanical
55 45-65 17 N/A N/A N/A Off Cycle N/A N/A
HA24FB,
HP24FO,
HP24FS,
HK24FO
Digital 0
-10 - +10
18 6 20
Air
Temp
Hot Gas
10 Hrs
2 Mins
3 Mins
HB24FS
Electro-Mechanical
0
-10 - +10
14 N/A N/A N/A Hot Gas
6 Hrs
10 Mins
N/A
HC24FS
Electro-Mechanical
0
-10 - +10
14 N/A N/A N/A Hot Gas
220
Mins
20 Mins
N/A
HC24BB
Digital 42 30-48 15 0 N/A
Set
Point
Off Cycle N/A N/A
HC24RB,
HC24RO,
HC24TB,
HC24TO
Digital 34 30-42 15 0 N/A
Set
Point
Off Cycle N/A N/A
HC24WB
Digital 43 40-68 10 0 N/A
Set
Point
Off Cycle N/A N/A
HH24BO,
HH24BS
Digital 42 30-48 15 6 20
Air
Temp
Off Cycle N/A N/A
HH24RO,
HH24RS
Digital 34 30-42 15 6 20
Air
Temp
Off Cycle N/A N/A
HH24WO,
HH24WS
Digital 43 40-68 10 6 20
Air
Temp
Off Cycle N/A N/A
HP15BO,
HP15BS,
HK15BO
Digital 42 30-48 15 0 20
Air
Temp
Programmed
12 Hrs
15 Mins
N/A
Return to Table of Contents
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Factory Set Point
Table 8-20. Factory Temperature Settings
Electrical System Repair Instructions Page 8-27