EasyManuals Logo
Home>Philips>TV>55PUS7303/12

Philips 55PUS7303/12 User Manual

Philips 55PUS7303/12
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
5.2.3 Error codes overview
In this chassis only “layer 2” error codes are available and point to problems on the SSB. They are triggered by LED blinking
when CSM is activated. Only the following layer 2 errors are defined:
5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
• By using the CLEAR command in the Factory mode:
• By using the following key sequence on the remote control transmitter: “062599” directly followed by the OK button.
• If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips 55PUS7303/12 and is the answer not in the manual?

Philips 55PUS7303/12 Specifications

General IconGeneral
BrandPhilips
Model55PUS7303/12
CategoryTV
LanguageEnglish

Related product manuals