Keypads
PIMA Electronic Systems 9
2.3.2 Technical specifications
Communication voltage levels: 0, +12V
Operating Voltage Range: 9-14 VDC
Current Consumption: 50mA idle, 90mA max.
Sizes: 15 x 12 x 2cm
Weight: 163gr
CE compliance
Operating Temperature: -10 to +55 °C
Humidity (Max.): 93% R.U., Non-
condensing.
2.3.3 Quick guide
For the system status LEDs, refer to page 6.
For
Keypad alarms
, see section 2.1.5 above.
Silencing the keypad
To silence the keypad’s buzzer (including the chime) and keys completely, press together the
and keys. Press again to re-activate the buzzer (toggle).
Operation keys
Press and hold the keys described in the next table, for the following operations:
Key
Operation
1-4
Arm to
Home 1-4
modes
*
Turn on/off the chime
Technical specifications
Powered by 13.8VDC, nominal
Operating Voltage Range: +9 to +14 VDC
Current consumption:
Min.: 50mA, Max.: 90mA

Other manuals for Pima FORCE