Sensitivity for
137
Cs , not less
Variation of the energy response relative to the
typical one (Annex A), no more
Range of coefficient n (number of mean square
deviations)
Relative intrinsic error of count rate measurement
in range from 10 to 9999 s
-1
False alarm rate, not more
Detection of a source moving at 0.2 ±0.005 m
distance and 0.5±0.05 m/s velocity (
background
not more than 0.25 µSv/h)
Additional relative intrinsic error of count rate
measurement:
- temperature and humidity variations
normal to high
- temperature variations from normal to low
(-15
o
C)
- extreme values of supply voltage
instrument set up via IR interface
Temperature range
Relative humidity
From -30 to +50 °С (LCD: -15
The instrument withstands
- RF Electromagnetic Fields:
1) 10 V/m in frequency range from 8
2) 30 V/m in frequency range from 800
2500 MHz;
- DC and AC Magnetic Fields
Sine Vibrations in frequency range
from 10 to 55 Hz with acceleration
Electrostatic Discharges 8 kV (air
discharge), 6 kV (contact discharge)