Chapter 4 Main circuit and terminal wiring
12
Motor
R
Three-phase 380V AC
S
T
U V W
Figure 4.5
4-3.PR5200C external terminal description
4-4-1. Terminal 3,4 is programmable relay,output and function set by the setting item PE, as
normally open dry contact.Contact capacity is:AC 250V/5A.
4-4-2. Terminal 5, 6 as fault output,when the soft starter failure or loss of power closed, when
the soft starter normal open, contact capacity is:AC 250V/5A
4-4-3. Terminal 11, 12 as 0 to 20ma, 4 to 20ma DC analog output, use for real-time
monitoring current,when the full scale is 20ma,the instruction motor current is four times as the
soft starter nominal rated current,you can external 0 to 20ma, 4 to 20ma DC ammeterto observate,
the output load resistance max value is 300 ohm. Remark: The machine defaults to 4 ~ 20ma
output, if need 0 ~ 20ma output please explain in order.