Chapter 5 Control panel and operation
16
5-2 Function parameters setting and description
Function parameters code in the following table
Voltage slope model is effective, the starting
voltage of current mode is 40%.
Limiting current mode does not work.
Setting 0 means free stopping, please set 0 for
one with two onnections .
The minimum time between two successive
start, the function of protecting thyristor.
0 for Chinese display, 1 for the English
display.
The current limiting mode is effective; the
maximum flow value of the voltage slope
mode is 400%.
Relative to the value of the rated current PP.
Protection below the set value.
Protection is higher than the set value.
0 limit current; 1 voltage; 2 jump; limit
current; 3 jump + voltage; 4 current ramp; 5
double closed loop; 6 monitoring.
0 primary; 1 light load; 2 standard; 3 heavy
load; 4 advanced.
0 keyboard; 1 keyboard + external control; 2
external control; 3 external control +
communication; 4 keyboard + external control
+ communication; 5 keyboard +
communication; 6 communication.
Parameter
modification allowed
See 5.5 other setup instructions.
For MODBUS native slave address setting.
See 5.3 programmable relay output functions.
See 7.3.1 soft stop mode.
Nominal rated current for input motor.