29 © 2014 Proceq SA
6. Technical Specifications
Instrument
Cover Measuring Range Up to 185 mm (7.3 inch), see Figure 2
Cover Measuring Accuracy ± 1 to ± 4 mm (0.04 to 0.16 inch),
see Figure 2
Measuring Resolution Depending on diameter and cover,
see Figure 3
Path Measuring Accuracy
on smooth Surface
± 3 mm (0.12 inch) + 0.5 % to 1.0 % of
measured length
Diameter Measuring Range Cover up to 63 mm (2.50 inch), Diame-
ter up to 40 mm (# 12)
Dia. Measuring Accuracy ± 1 mm (± # 1)
Display 7” colour display 800x480 pixels
Memory Internal 8 GB Flash memory
Regional Settings Metric and imperial units and multi-
language supported
Power Input 12 V +/-25 % / 1.5 A
Dimensions 250 x 162 x 62 mm
Weight (of display device) About 1525 g (incl. Battery)
Battery Lithium Polymer, 3.6 V, 14.0 Ah
Battery Lifetime > 8h (in standard operating mode)
Max. Altitude 3000 m above sea level
Humidity < 95 % RH, non condensing
Operating Temperature 0°C – 30°C (Charging*, instrument on)
0°C – 40°C (Charging*, instrument off)
-10°C – 50°C (Non-charging)
Environment Suitable for indoor & outdoor use
IP Classification Touchscreen IP54, Probe IP67
Pollution Degree 2
Installation Category 2
Standards and Guidelines BS 1881 part 204, Din 1045,
SN 505262, DGZfP-guideline B2,
CE certification
*charging equipment is for indoor use only (no IP classification)
Power Supply
Model HK-AH-120A500-DH
Input 100-240 V / 1.6 A / 50/60 Hz
Output 12 V DC / 5 A
Max. Altitude 3000 m above sea level
Humidity < 95%
Operating Temperature 0°C - 40°C
Environment Indoor use only
Pollution Degree 2
Installation Category 2