Center Line (CL)
*When an Arrow LED lights up move the
probe along the rebar axis until MC LED
14
or
15
lights up. Then the MC is
precisely above a rebar axis.
By pushing
12
and
13
simultane-
ously the cursor jumps to the next line
(in Multi-Line, Area-Scan and Cross-Line
Mode only)
13
Short: Measure diameter
Long: Zeroing
15
Measurement Center when
Spot range is set (MC Sp)
Measurement Center when Standard,
Large or Auto range is set (MC SLA)
Short: Start / Stop
Long: Set marker
12
14
17
Arrow LED indicates proximity of rebar*
Arrow LED indicates proximity of rebar*
17