MAINTENANCE
Changing Oil
Place generator on a level surface.
Run the generator for several minutes until the engine is warm. Turn off generator.
Remove screws, then remove outer casing side cover.
Remove the crankcase dipstick.
Place an oil pan underneath the engine. Tilt generator to collect used oil. Allow oil to drain completely.
Return generator to a level surface.
(Crankcase Dipstick hole).
Use a clean rag to wipe up any spilled oil.
Replace crankcase dipstick.
Reinstall outer casing side cover and tighten screws.
Recommended Engine Oil: SAE 10W-30
Recommended Engine Oil Grade: API Service SE type or higher quality of engine oil.
Engine Oil Quantity: 0.59L (20.2 oz)
Make sure no foreign matter enters the crankcase
CAUTION!
the engine.
CAUTION!