3.2 Keypad Indications
Supply
Rest of the World
Denmark, Norway, Finland &
Sweden
Illuminated Correct AC & DC power sources AC power is OK
Blinking Indicates DC source (battery) fault Indicates an AC fault
Extinguished
Indicates AC fault / no power to
panel
No power to the panel
Ready
Illuminated OK to Arm, no open zones
Blinking Programming function is active
Extinguished One or more open zones
Alarm
Illuminated In Log: FTA - zone activation
Slow Blinking Active alarm in FTA mode.
Fast Blinking A latched alarm or fault needs clearing ‘VIEW THE LOG’
Extinguished No active alarms
Tamper
Illuminated Indicates a tamper condition (used in log display)
Blinking Indicates a tamper condition in FTA mode
Extinguished No tamper alarm active
P.A.
Illuminated Indicates a PA alarm condition (used in log display)
Blinking Indicates a PA alarm condition in FTA mode
Extinguished No PA active
Fire
Illuminated Indicates a Fire alarm condition (used in log display)
Blinking Indicates a Fire alarm condition in FTA mode
Extinguished No Fire alarm active
Fault
Illuminated Indicates a system Fault
Blinking Keypad is in engineers mode
Extinguished No Fault active
Armed
Illuminated The panel is armed
Blinking Indicates the panel is arming with omitted zones
Extinguished The panel is not armed
Disarmed
Illuminated The panel is disarmed
Blinking Keypad is in user menu mode
Extinguished The panel is not disarmed