76
Display
• Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while
setting, then shows the actual(±5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90% RH(Relative Humidity).
• Error Codes:
EH60 - Room temperature sensor error - Unplug the unit and plug it back in. If error
repeats, call for service;
EH61 - Tube Temperature sensor of the evaporator error - Unplug the unit and plug it
back in. If error repeats, call for service;
EH0b - Display board and master control board communication error.Unplug the unit
and plug it back in. If error repeats, call for service;
• Protection Code:
P2 - Bucket is full - Empty the bucket and replace it in the right position.
Eb - Bucket malfunction--Replace the bucket in the right position, the malfunction
clear.
G
NOTE
When one of the above malfunctions occurs, turn off the unit, and check for
any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer or its service
agents or a similar qualified person for service.
CONTROL PANEL FEATURES
Auto Defrost
When forst builds up on the evaporator coils, the compressor will cycle off and the fan will
continue to run until the frost disappears.
Note: When Auto defrosting operation, the unit may make a voice of refrigerant flowing,
it is normal.
Auto Shut Off
The dehumidifier shuts off when the bucket is full. For some models, the fan motor will
continue to run for 30 seconds.
Wait 3 minutes before resuming operation After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the unit. Operation will automatically
start after 3 minutes.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous
function setting automatically when the power resumes.
Continuous dehumidifying mode
At continuous dehumidifying mode, the unit dehumidify continuously and cannot select
humidity. Press mode button to exit continuous dehumidifying mode.
Smart dehumidifying mode(On some models)
At smart dehumidifying mode, the unit will automatically control room humidity in a
comfortable range 45%~55% according to the room temperature. The humidity setting
function will be invalid.
4
Setting dehumidifying mode
At setting dehumidifying mode, the unit can be adjusted in a range 35%~85%, and the
humidity setting can be adjusted (increase/decreasing) in 5%. Press MODE button to exit
setting dehumidifying mode.
Quick glance light(On some models)
When the humidity is more than 70%, the quick glance light will emit red light.
When the humidity range is at 45% to 70%, the quick glance light will emit yellow light.
When the humidity is lower than 45%, the quick glance light will emit green light.
The light can be activated or deactivated by pressing and holding the Fan button and UP
botton simultaneously for 2 seconds.
MAX mode(On some models)
The unit can make the MAX dehumidification function when it is under MAX mode. The
fan speed is fixed at high fan speed.
Dryer mode(On some models)
The unit can make the MAX dehumidification function when it is under Dryer mode. The
fan speed can’t be adjusted.
NOTE:
1. The Dryer/MAX(model dependent) mode must be operated in a close room,do not
open the door and window.
2. To make the best effective dehumidification, please first dehydrate the wet clothes.
3. Make sure to direct airflow at the wet clothes.
4. For thick and heavy wet clothes may not get the best effective dehumidification.
Bucketless mode(on some models)
The dehumidifier can be used without bucket when the unit is under Bucketless mode.
The unit will not reminds the water to be full after entering the bucketless mode,
therefore, it is suggested that:
1. Check whether the tube is properly connected;
2. Link the other end of the tube to a place with unlimited capacity, such as a sink or a
basin;
3. Do not place the other end of the tube in a container with limited capacity, otherwise
the water may overflow to the floor.
Exit the bucketless mode:
1. Press FILL LEVEL and up to exit
2. Turn off the power
NOTE: It may cause an unexpected exit from the bucketless mode when the tank float
touches the micro switch (at the bottom of the unit). So please check whether the bottom
of the unit is clear under the bucketless mode.
Note:
1. Please make sure the unit is placed on a flat, horizontal table to prevent toppling and
sliding.The tilt angle needs to be less than 1 degree.
man_D720 Cube ('21) V3.indd 76man_D720 Cube ('21) V3.indd 76 05-07-2021 14:1605-07-2021 14:16