connectorstoconnectthe4wiresfromtheremotesensortotheuser-suppliedinterconnectwire.Besuretokeep
propercolorsattachedtoeachother.
3.Sensormounting:
Youwillneedtwoscrewstomountthesensor.Usethetwoslottedholestomountthebaseofthesensortothe
wallandthensnapthecoverintoplace.
4.Controllerconnection:
Usetheprovidedspliceconnectorstoconnectthe4wiresfromtheDEH3000Rtotheuser-suppliedinterconnect
wire.Besuretokeepthepropercolorsattachedtoeachother.
Continuewiththeinstallationasdescribedintherestofthismanual.
2.5 Control Panel Wiring Instructions
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.
WARNING! THE QUEST DEH 3000R DIGITAL CONTROL OPERATES ON A LOW
VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE
CIRCUIT.
WARNING! UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000R.
Theinstallermustsupplyalleldwiring,includingthewiringbetweentheQUESTdehumidierand
theQuestDEH3000R.SomeofthecontrolwiresleavingtheQUESTdehumidiermaynotbeused
insomecontrolsituationsandshouldbeleftdisconnectedwithwirenutstapedontothestripped
ends.
BesuretoconsulttheelectricalschematicinthismanualortheinternalelectricalboxoftheQuest
dehumidierbeforemakinganycontrolconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.