Quicksilver 755SD — System & Component Overview and Operaon
23
To Winterize the Grey Water System:
1. Empty the grey water holding tank via the dockside pumpout.
2. Pump water through the system to remove any residue materials.
3. Empty the grey water holding tank again, removing all liquids.
4. Pour an environmentally safe anfreeze (Propylene Glycol based) in each sink and allow to
drain or pump to the holding tank.
5. Bilge Pumps
Your vessel is equipped with two bilge pumps, with one located in the a secon of the boat, and the
second one located in the forward part of the boat. Access to the a bilge pump is via the motorwell
access plate, while access to the forward bilge pump is through a hatch located in the a berth oor.
Both bilge pumps are rated for 500 GPH, and are acvated automacally by a built in mercury free
oat switch when the water in the bilge reaches a predetermined level. You can also manually operate
the bilge pump at the console by pressing the bilge pump switch.
Inspect the bilge pump intakes and keep them free of dirt or material which may impede the ow of
water through the pump. To clean the pump strainer, depress the lock tabs on both sides of the pump
and li the pump motor.
If water does not come out of the discharge hose:
1. Remove the motor module to see if the impeller rotates with the power on.
2. Remove any debris that may have accumulated in the nozzle secon or strainer base.
3. Check hose and connecon on hull side for debris and proper connecons.
Check the funcon of all bilge pumps at regular intervals.
Clear pump inlet from debris.
The bilge pumping system is not designed for damage
control.
Grey Water System
Entertainment center sink drain
Entertainment center sink drain hose
Grey water tank
Tank pumpout hose
Pumpout deck plate
Tank vent hose
Tank vent thru hull