EasyManuals Logo
Home>Quincy Compressor>Water Pump>QSVI Series

Quincy Compressor QSVI Series User Manual

Quincy Compressor QSVI Series
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Section 5- Maintenance
Or Service Preparation
Pre~aring for Maintenance or Service
!W~~G!
Never assume the vacuum pumps ready for
maintenance or service because it is stopped. The
automatic stop-start control may start the vacuum
pump at any time.
The following procedure should be used for maximum
safety when preparing for maintemnce or service:
.
.
.
.
Per OSHA regulation 1910.147: The control of
Hazardous Ener~ Source (Lockout/Tagout),
disconnect and lock-out the main power switch
and hang a si~ at the switch of the unit being
serviced
Close shut-off valve ahead of the inlet valve and
after the air/lubricant reservoir (if so equipped) to
prevent any air flow through or pressure buildup in
the vacuum pump. NEVER depend upon a check
valve to isolate the system.
Manually vent the vacuum system to atmospheric
pressure.
Shut off water and pressurization system if it is water
cooled.
Page 43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quincy Compressor QSVI Series and is the answer not in the manual?

Quincy Compressor QSVI Series Specifications

General IconGeneral
BrandQuincy Compressor
ModelQSVI Series
CategoryWater Pump
LanguageEnglish

Related product manuals