14 ESP-LXIVM Controller Troubleshooting Guide
Table of
Contents
Shorted Paths
The controller has automatically entered Short Finding
Mode to protect itself against a short on the 2-wire path
Press the Down Arrow button to select
Test Shorted Paths, then press Next
Turn the dial to Diagnostics and select
Diagnostics from the menu, then press Next
Press the Down Arrow button to select
the Path (1-4) to test, then press Next
Next Page
Press and hold the Yes button
to energize the selected path
Note: Irrigation will be disabled
Trouble Shoot in the Field using a milliamp meter.
A sharp increase in current should be observed
right before the Short Condition in 2-wire Path.
If issue cannot be resolved using the Shorted Paths Test, refer
to the Shorted Path (Manual Method) on the next page.
NOTE: Shorted Path will
display “Fault.