P
ossiblecausesPossiblesolutions
P
owersourceinsufficient
Withtheproductunderload,usingamulti-meter,checkthe
powersupplyvoltageasclosetotheunitaspossibletoestablish
actualvoltagewhenthecurrentisflowing.(Checkyourproduct’s
Technicalspecificationforpowersupplyrequirements.)
Damagedorfouled
transducer
Checktransducercondition,ensuringitisnotdamagedandisfree
fromdebris/fouling.Ifnecessary
,cleanorreplaceyourtransducer.
Aftercleaningorreplacementcoatthetransducerusinga
water-basedanti-foulingpaint.
Damagedcables
1.Checktheunit’ sconnectorforbrokenorbentpins.
2.Checkthatthecableconnectorisfullyinsertedintotheunit
andthatthelockingcollarisinthelockedposition.
3.Checkthecableandconnectorsforsignsofdamageor
corrosion,replaceifnecessary.
4.Withtheunitturnedon,tryflexingthepowercableneartothe
displayconnectortoseeifthiscausestheunittore-boot/loose
power,replaceifnecessary.
5.Checkthevessel’sbatteryvoltage,theconditionofthebattery
terminalsandpowersupplycables,ensuringconnectionsare
secure,cleanandfreefromcorrosion,replaceifnecessary.
6.Withtheproductunderload,usingamulti-meter,checkforhigh
voltagedropacrossallconnectors/fusesetc(thiscancausethe
Fishfinderapplicationstostopscrollingortheunittoreset/turn
off),replaceifnecessary.
V esselspeedtoohigh
Slowvesselspeedandrecheck.
Bottomtooshallowortoo
deep
Thebottomdepthmaybeoutsideofthetransducersdepthrange ,
movevesseltoshallowerordeeperwatersasrelevantandrecheck.
P oor/problematicimage
P ossiblecausesPossiblesolutions
T argetswillappeardifferently
ifyourvesselisstationary(e.g.:
fishwillappearonthedisplayas
straightlines).
Increasevesselspeed.
Scrollingpausedorspeedsettoo
low
Unpauseorincreasesonarscrollingspeed.
Sensitivitysettingsmaybe
inappropriateforpresent
conditions.
CheckandadjustsensitivitysettingsorperformaSonarreset.
Damagedcables
1.Checktheunit’ sconnectorforbrokenorbentpins.
2.Checkthatthecableconnectorisfullyinsertedintothe
unitandthatthelockingcollarisinthelockedposition.
3.Checkthecableandconnectorsforsignsofdamageor
corrosion,replaceifnecessary.
4.Withtheunitturnedon,tryflexingthepowercablenear
tothedisplayconnectortoseeifthiscausestheunitto
re-boot/loosepower,replaceifnecessary.
5.Checkthevessel’sbatteryvoltage,theconditionofthe
batteryterminalsandpowersupplycables,ensuring
connectionsaresecure,cleanandfreefromcorrosion,
replaceifnecessary.
6.Withtheproductunderload,usingamulti-meter,check
forhighvoltagedropacrossallconnectors/fusesetc(this
44

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine HYPERVISIONT HV-300 Series and is the answer not in the manual?

Raymarine HYPERVISIONT HV-300 Series Specifications

General IconGeneral
BrandRaymarine
ModelHYPERVISIONT HV-300 Series
CategoryTransducer
LanguageEnglish

Related product manuals