EasyManuals Logo
Home>Redarc>Battery Charger>BCDC1225D

Redarc BCDC1225D User Manual

Redarc BCDC1225D
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
8
2 INSTALLATION
2.2 Charge Profi le Selection (ORANGE Wire)
The ORANGE wire is used to select the Maximum output voltage. This is achieved
by connecting in the following way:
To select Profi le A leave the ORANGE wire disconnected. This will set the
Maximum voltage to 14.6V.
To select Profi le B connect the ORANGE wire to Common Ground. This will set
the Maximum voltage to 15.0V.
To select Profi le C connect the ORANGE wire to the RED wire (Input source
positive). This will set the Maximum voltage to 15.1V.
To select the Li Profi le connect the ORANGE wire to the GREEN wire (LED
output). This will set the charger to Lithium mode.
Check the manufacturer’s data for your battery and ensure that the Maximum voltage
of the profi le you select does not exceed the manufacturer’s recommended maximum
charging voltage. If the Maximum voltage is too high for your battery type, please select
another charging profi le.
Not
Connected
Orange Wire
Orange Wire
Orange Wire
Red Wire
Input
Source
Positive
Midi
Fuse
Green Wire
Optional
LED
Orange Wire
Figure 2.2.1 - Charge Profi le Selection

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Redarc BCDC1225D and is the answer not in the manual?

Redarc BCDC1225D Specifications

General IconGeneral
BrandRedarc
ModelBCDC1225D
CategoryBattery Charger
LanguageEnglish

Related product manuals