8
2 INSTALLATION
2.2 Charge Profile Selection (ORANGE Wire)
The ORANGE wire is used to select the Maximum output voltage. This is achieved
by connecting in the following way:
To select Profile A leave the ORANGE wire disconnected. This will set the
Maximum voltage to 14.6V.
To select Profile B connect the ORANGE wire to Common Ground. This will set
the Maximum voltage to 15.0V.
To select Profile C connect the ORANGE wire to the RED wire (Input source
positive). This will set the Maximum voltage to 15.3V.
To select the Li Profile connect the ORANGE wire to the GREEN wire (LED
output). This will set the charger to Lithium mode.
Check the manufacturer’s data for your battery and ensure that the Maximum voltage
of the prole you select does not exceed the manufacturer’s recommended maximum
charging voltage. If the Maximum voltage is too high for your battery type, please select
another charging prole.
Not
Connected
Orange Wire
Orange Wire
Orange Wire
Red Wire
Input
Source
Positive
Midi
Fuse
Green Wire
Optional
LED
Orange Wire
Figure 2.2.1 - Charge Prole Selection