Revision 2.3 Page 10 of 14
Warning
Please Note
The specifications of the product detailed on this
Set-Up Guide may change without notice. RDM
Ltd. shall not be liable for errors or for incidental
or consequential damages, directly and indirectly,
in connection with the furnishing, performance or
misuse of this product or document.
ML Multistage Thermostat Installation Guide
www.resourcedm.com
IP-L
To use the ML controller in IP-L mode, you will require either a PR0016 Mercury IP Module or PR0018 Mercury Hub.
The rotary switches must be set to 000 on the comms module or 00 on the Hub
In this mode the IP address and gateway address must be set up manually in the controller.
Use the following table as a guide: -
Display
Option
IP1
IP Address byte 1
IP2
IP Address byte 2
IP3
IP Address byte 3
IP4
IP Address byte 4
nL
Network Mask Length (see table below)
GT1
Gateway Address byte 1
GT2
Gateway Address byte 2
GT3
Gateway Address byte 3
GT4
Gateway Address byte 4
ESC
Exit network menu. N.B. this option must be selected to save
any changes made in this menu
Setting nL
To ease setup, a single network mask length value is used. If the address has been specified with a network mask value in dotted IP
format e.g. 255.255.255.0 then the table below gives the conversion:
Mask
Length
Mask
Length
Mask
Length
255.255.254.0
23
255.254.0.0
15
255.255.255.252
30
255.255.252.0
22
255.252.0.0
14
255.255.255.248
29
255.255.248.0
21
255.248.0.0
13
255.255.255.240
28
255.255.240.0
20
255.240.0.0
12
255.255.255.224
27
255.255.224.0
19
255.224.0.0
11
255.255.255.192
26
255.255.192.0
18
255.192.0.0
10
255.255.255.128
25
255.255.128.0
17
255.128.0.0
09
255.255.255.0
24
255.255.0.0
16
255.0.0.0
08
The network led will start flashing as the controller is logging on to the network; once logged on, the LED stays on.
485 Networks
RS485 Relay Board will support the following protocol :-
Genus
Use the controller menu options to set-up the network; press enter at the “net” screen, then choose from the following network set-up
screens:
Display
Option
485t
485 Network Type
485A
485 Address/Name
gAdd
Show underlying network address assigned to
controller
rLog
Re-log the controller back onto the network
CLrA
Clear the address/name from the controller
ESC
Exit network menu. N.B. this option must be selected to save any changes
made in this menu

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resource Data Management PR0122-STA and is the answer not in the manual?

Resource Data Management PR0122-STA Specifications

General IconGeneral
BrandResource Data Management
ModelPR0122-STA
CategoryThermostat
LanguageEnglish

Related product manuals