EasyManuals Logo
Home>Revox>Tape Deck>C115

Revox C115 User Manual

Revox C115
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
REVOX®
43.3
Aligning
the
erase
frequency
Switch
on
the
cassette
recorder
and
activate
the
record
mode.
Connect
the
frequency
counter
to
pin
6
of
the
edge
connector
JK
31.
Adjust
the
frequency
to
105
kHz
by
aligning
the
core
of
transformer
LL
01.
4.3.4
Aligning
the
erase
and
record
head
Switch
on
the
cassette
recorder
and
activate
play
mode.
;
Connect
the
oscilloscope
with
10:1
probe
to
the
inter-
section
C
909
/
913.
By
tuning
the
core
of
transformer
L901
align
the
reso-
nant
circuit
of
the
left-hand
channel
to
a
clean
sinusoidal
shape.
Connect
the
oscilloscope
probe
to
the
intersection
C910/914.
By
tuning
the
core
of
the
transformer
L
902,
align
the
sine-wave
shape
of
the
right-hand
channel.
Note:
For
the
RF
measurements
described
in
Sec-
tions
4.3.3
and
4.3.4,
the
test
points
should
be
loaded
with
max.
20
pF,
otherwise
the
adjustment
will
not
be
optimal.