E
18
C11
REVOXx®
4.3
Audio
alignments
All
adjustment
controls
for
this
work
are
located
on
the
audio
board.
4.3.1
Peak
meter
-
Connect
the
AF
generator
to
the
AUDIO
IN
sockets.
7
rf
-
Connect
the
AF
millivoltmeter
to
the
AUDIO
OUT
sockets
L,
R.
-
Set
the
OUTPUT
LEVEL
switch
to
the
0
dBu
position.
-
Press
the
REC
key
to
switch
to
SOURCE
(Rec/
4
Pause).
-
From
the
generator
feed
a
1
kHz
sine-wave
signal
so
that
a
level
of
775mV
appears
on
the
output.
-
With
the
trimmer
RX
01
(left)
and
RX
02
(right)
adjust
1
~
toOdB.
4
-
Lower
the
input
level
by
35
dB
and
adjust
the
trimmer
RX
31
in
such
a
way
that
only
the
first
segment
lights
up
on
the
peak
meter.
4.3.2
Frequency
response
with
tape,
MPX
filter
-
Frequency
response
check
(level
0
dB
display,
freq.
30
Hz
-
18
KHz
+/-1
dB)
-
Feed
19
kHz
0
level
0
dB
display
to
the
INPUT
sockets.
-
Switch
the
recorder
to
REC/Pause
by
pressing
the
REC
key.
-
Switch
on
the
MPX
filter.
-
Adjust
the
coils
L
651
and
L
652
to
minimum
level.
The
level
should
be
attenuated
by
at
least
30
dB.