Air
Dimensional Data
RGPQ Series
7
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
Horizontal Dimensions and Clearance to Combustible Material (inches) [mm]
MODEL
RGPQ-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05
14 [356] 12
27
/32 [326] 10
5
/8 [270]
➀
11
1
/2 [292]
0
4 [102]
➁
0 1 [25] 3 [76]
6 [152]
➂
LEFT
SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [kg]
85 [38.6]
07
17
1
/2 [445] 16
11
/32 [415] 12
3
/8 [314]
➀
15 [381]
0
3 [76]
➁
0 1 [25] 3 [76]
6 [152]
➂
105 [47.6]
10 (A) 17
1
/2 [445] 16
11
/32 [415] 12
3
/8 [314]
➀
15 [381] 0
3 [76] ➁
0 1 [25] 3 [76]
6 [152] ➂
115 [52.2]
10 (B)
21 [533] 19
27
/32 [504] 14
1
/8 [359]
➀
18
1
/2 [470]
0
0
0 1 [25] 3 [76]
6 [152]
➂
120 [54.4]
12 24
1
/2 [622] 23
11
/32 [593] 15
7
/8 [403]
➀
22 [559] 0 0 0 1 [25] 3 [76]
6 [152] ➂
140 [63.5]
15 24
1
/2 [622] 23
11
/32 [593] 15
7
/8 [403]
➀
22 [559] 0 0 0 1 [25] 3 [76]
6 [152]
➂
150 [68]
F
1
7
/8 [48]
2
1
/2 [64]
2
1
/2 [64]
2
1
/2 [64]
2
1
/2 [64]
2
1
/2 [64]
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with
local codes.
[ ] Designates Metric Conversions
Horizontal Dimensions