15
In-series Gas Boosting
Temperature controllers must not be fitted if this water heater is installed
as part of a solar water heater system because water at a temperature
much higher than the controller setting can be delivered.
If a solar pre-heater has been installed to an existing Integrity water heater
installation then a solar bypass valve or a comparator must be fitted at this
water heater and any controllers, if fitted, must be disconnected and
removed. Note: models 871024-C and 871026-B do not require a solar
bypass valve or a comparator.
18 litre Integrity’s are NOT suitable for use as in series gas booster.
871020-B, 871024-C and 871026-B Models
Where one of the above listed model Integrity is installed to provide in-series gas boosting
a solar bypass valve or a comparator is not required. These models have had a change
made to the operating software which eliminates the need for either of these components.
The software now electronically mimics a bypass valve so that when the inlet water
temperature is above 58°C the fan and burner will not operate despite water flowing
through the heat exchanger. When the inlet water temperature is less than or equal to
58°C the burner will fire and boost the outlet temperature to 60°C provided the flow rate is
greater than 3 litres per minute. 20 and 26 models with modified software can be identified
by a B suffix in the model number, whereas a 24 model with modified software can be
identified by a C suffix in the model number i.e. 871024NF-C.
The preset outlet temperature of the Integrity, when installed as an in-series gas booster to
a solar water heater, must be set at 60 C for the system to operate correctly.
The factory preset outlet temperature of all Integrity models is 55 C; during a new
installation it will be necessary to reset the outlet temperature to 60 C. Refer to page 4 for
details on checking and adjusting the outlet temperature.
Note: If a 20, 24, 24B or 26 model heater is replaced with an 20B, 24C or 26B model
heater and the existing 20, 24, 24B or 26 heater is used as an in-line booster and has a
solar bypass valve fitted, the solar bypass valve must be removed and the plumbing
connections remade directly to the Integrity inlet and outlet water connections (refer to
diagrams on pages 15 & 16).
In-series Gas Boosting Integrity Solar Loline Installation
Note: This plumbing diagram is
also applicable to standard
model heaters fitted with a
comparator.
For more information on
comparators refer to page 17.